Refer to documentation Implementation
Presentation
Close
Fields
The following fields are present on this tab :
Block number 1
| Process code. It must be used in the process dictionary. |
| sub-program or function considered as re-usable and as a result to be capitalized on in this dictionary. |
| Descriptive title for the sub-program or the function. Must be clearer and more precise to then facilitate the searches. |
Characteristics
| An activity code is used to:
In this way, if the activity code is disabled, the marked element will not be useable, and the associated code (if any) will neither be generated nor can be activated. |
| Whether the module is active or not has no impact on the execution of the sub-program. |
| Used to sort the sub-programs and functions in order to facilitate the search, for better reusability. The sub-programs and functions should be sorted according to their purpose:
|
| Used to specify that this sub-program or function can be generated for the web services. In fact, no process is shipped that can be directly used for the web services. However, a services web generationfunction is available for the objects and sub-programs identified as being suitable for generation. |
|   |
Block number 3
| Check box that is used to make the distinction between the functions (called by the instruction Func ) and the sub-programs (called by the instruction Call.) |
| This field should be assigned for the functions. The latter should be sorted according to the nature of their return argument.
|
Description
| Text loading the PRE "presentation" paragraph, in the record help. In the documentation management, the record help is identified by :
|
Grid Parameters
|   |
| Each parameter is identified with a 10 character code (uppercase and numbers). There is no dictionary for these parameters. |
| Parameter title for the sub-program or the function. Must be clearer and more precise to facilitate understanding. |
| Nature of the parameter :
|
|   |
| Dimension of the parameter |
| It indicates how the parameter is passed. by address ( a variable is necessary to pass the parameter. On exiting the sub-program, the value of any modified parameter is returned to the calling process). by value ( the parameter is passed by a variable or by a constant. On exiting the sub-program, the value of the parameter even if it is modified is not returned to the calling process). |
Close
Action icon
Button that is used to update the parameters grid following the analysis of the sub-program. The fields loaded automatically are : the parameter code, the type and the argument type. Then it is necessary to complete this grid by entering the parameter title and dimension.
Close
This button is used to copy the sub-program definition to another folder. |
This button is active in the sub-programs authorized in Web services. It is only used for the current sub-program in web services. |
The Coherence verification process for the parameters grid with the sub-program. The number of parameters with errors is then displayed if any exist.
The Coherence verification process for the parameters grid with all the sub-programs. A log file is generated at the end of the verification process.
This menu used to access by tunnel to the function "formula assistant context".
This choice of menu allows to zoom to the documentation management, on the first documentation paragraph (if it exists) related to the current record.
This choice of menu allows to zoom on the dictionary link management function. This function allows to establish links between the current record and other records (for example links between functions and parameters). These links, dedicated for documentation purpose, allows the generation of documentation structure.
This choice of menu allows to generate the documentation. Three types of generation can be separately or simultaneously started :
The ranges and parameter proposed by default are defaulted according ti the current record, but they can be changed during the execution.
In addition to the generic error messages, the following messages can appear during the entry :
Process does not exist in the current folder or in one of the parent folders.
The entered process code is a code reserved for Adonix, and it therefore cannot be used.